Screen sightlines in a meeting room: how far back the last seat can go
Curtin and Flinders publish 5.3 times image height, Melbourne publishes 6, and AVIXA publishes no multiple at all. Which rule decides the longest boardroom table that fits, and why the seat nearest the screen is the one that fails.

Australian university audiovisual standards put the last seat between 5.3 and 6 times the image height from the screen, and the nearest seat no closer than about twice it. Curtin and Flinders both publish a maximum viewing distance of 5.3 times image height and a closest viewing distance of 2 times. The University of Melbourne publishes 6 times as the furthest viewer and 1.732 times as the closest. On a 997 mm image height, an 80 inch 16:9 panel, that is a back row at 5.3 m or 6.0 m and a front seat no nearer than 2.0 m. Those two numbers, not the shape of the room, decide how long the meeting table can be.
This is the question that arrives late. The table is drawn, the chairs are scheduled, the audiovisual contractor is appointed after the furniture package, and then somebody works out that the person at the far end cannot read the screen. Furniture is cheap to change on paper and expensive to change once made, so the arithmetic belongs on the furniture drawing, not in the commissioning report.

The two numbers that size the room
Every published rule works from one dimension: the image height. Not the diagonal, not the panel's outside dimension, not the bezel. For a 16:9 image the height is a little over half the width, so an 80 inch diagonal gives a 1771 mm wide by 997 mm high image. Flinders publishes those viewable figures for nine sizes, which is useful because the number on a product sheet is a diagonal, and no part of the sightline arithmetic uses a diagonal.
From the image height come two distances. The furthest viewer limit decides whether the last seat can read content. The closest viewer limit decides whether the first seat can take in the whole image without moving their head across it. Both are expressed as multiples, and both are measured horizontally from the display surface to the viewer, not along the sightline.
The useful discipline is to run them in the other direction. A table at a published length sets the position of the last eye. Divide that distance by the multiple the project has adopted and the answer is a minimum image height, which maps onto a panel size. The screen then follows the furniture, rather than the furniture being squeezed around the biggest screen the budget allowed.
Which published rule applies, and who publishes nothing
There is no Australian Standard for this. What exists is a set of client design standards, published by universities because they build hundreds of rooms and have to tell consultants what good looks like, and an American national standard that most of them do not cite.
| Document | Furthest viewer | Closest viewer | Horizontal limit | Vertical limit | Bottom of image above floor (mm unless stated) |
|---|---|---|---|---|---|
| ANSI/AVIXA V202.01:2026 (DISCAS) | No single multiple published | Set by the 60 degree horizontal viewing area | 60 degrees from the perpendicular of each edge of the image | Vertical viewing factor, undefined below 50 per cent of the image height | Not published |
| University of Melbourne, Section 18, July 2026 | 6 times image height | 1.732 times image height | Within 45 degrees either side of the centre line | 30 degrees head tilt above horizontal | Not published |
| Flinders University, Version 1.2, 5 September 2025 | Less than 5.3 times image height | More than 2 times image height | 45 degrees from straight ahead to the furthest vertical edge | 35 degrees to the top of the image, 15 degrees to its centre | 1200 teaching, 1100 meeting |
| Curtin University, Part 6, Rev. 2, December 2019 | 5.3 times image height | 2 times image height | 45 degrees from the screen centre line | 15 degrees looking up to the screen centre line | 1.2 m classroom, 1.1 m meeting |
| University of South Australia, Revision 2.0 | Not published | Not published | Not published | Not published | Not published |
Two things in that table deserve attention before anyone quotes a figure in a tender.
First, the 5.3 and the 2 are not coincidence. Curtin states in section 5 that it adopts the rules of the AETM Design Guidelines, the Australasian audiovisual sector body's own document, and Flinders publishes the same pair of figures without naming a source. So the two documents are not independent agreement, they are one lineage. Melbourne's 6 and 1.732 are the second position, and 1.732 is the square root of three.
Second, UniSA publishes a thorough audiovisual specification with no viewing distance rule, no sightline angle and no bottom of image height at all. It specifies displays by room type instead, between 55 and 65 inches for a small meeting room and up to 86 inches for a large one. A project working to a client standard that is silent on sightlines is not exempt from the geometry, it simply has nobody to quote.
The platform vendors are no help either. Microsoft's published Teams Rooms planning pages give room sizes for focus, small, medium and large rooms in feet, with a deployment template whose Displays column is blank, and no viewing distance figure anywhere. Its guidance on furniture is one sentence: tables should be fixed and located in front of room displays, attached to the wall in smaller rooms but separated in larger ones for camera reasons.
From screen size to the back of the room
The Flinders table is the one to keep. It publishes the viewable width and height for each diagonal, then the maximum viewing distance at 5.3 times the height. The 2 times and 6 times columns here are arithmetic on the same published heights, so a project can read across to whichever rule it has adopted.
| Diagonal | Viewable image height (mm) | Closest viewer at 2 times (m) | Furthest viewer at 5.3 times (m) | Furthest viewer at 6 times (m) |
|---|---|---|---|---|
| 65 in (1651 mm) | 804 | 1.61 | 4.2 | 4.82 |
| 70 in (1780 mm) | 866 | 1.73 | 4.6 | 5.20 |
| 80 in (2032 mm) | 997 | 1.99 | 5.3 | 5.98 |
| 84 in (2130 mm) | 1057 | 2.11 | 5.6 | 6.34 |
| 90 in (2286 mm) | 1121 | 2.24 | 6.0 | 6.73 |
| 98 in (2490 mm) | 1214 | 2.43 | 6.4 | 7.28 |
| 100 in (2540 mm) | 1245 | 2.49 | 6.6 | 7.47 |
| 120 in (3050 mm) | 1495 | 2.99 | 7.9 | 8.97 |
| 130 in (3300 mm) | 1615 | 3.23 | 8.6 | 9.69 |
Melbourne publishes its own version of the same table, worked from 1.732 and 6 at 1080p, and it reaches further down the size range. A 43 inch panel gets a furthest viewer of 3.4 m, which is the figure that should end most arguments about whether a four person room can borrow a spare 43 inch screen.
| Panel diagonal | Closest viewer (m) | Furthest viewer (m) |
|---|---|---|
| 43 in | 1.1 | 3.4 |
| 49 in | 1.3 | 3.8 |
| 55 in | 1.4 | 4.3 |
| 65 in | 1.6 | 5.0 |
| 75 in | 1.8 | 5.8 |
| 85 in | 2.0 | 6.5 |
| 98 in | 2.3 | 7.4 |
Note what Melbourne says about which of its own rules bend. The furthest viewer rule "must be met and is considered essential". The closest viewer and horizontal angle rules are "somewhat flexible at the discretion of Audio-Visual Endpoints". That is an honest ranking, and it matches site experience: a back row that cannot read is a failed room, while a front seat that is slightly too close is a seat nobody chooses twice.
From screen size to table length
Now the furniture question. A boardroom table 900 mm off the display wall, with a seat at the head, puts the last eye roughly 1300 mm beyond the far edge of the top. Run the published multiples backwards from there and the minimum image height falls out.
| Table length (mm) | Last eye from the screen (mm) | Image height needed at 5.3 times (mm) | Smallest 16:9 panel | Image height needed at 6 times (mm) | Smallest 16:9 panel |
|---|---|---|---|---|---|
| 2400 | 3700 | 699 | 65 in | 617 | 65 in |
| 3000 | 4300 | 812 | 70 in | 717 | 65 in |
| 3600 | 4900 | 925 | 80 in | 817 | 70 in |
| 4200 | 5500 | 1038 | 84 in | 917 | 80 in |
| 4800 | 6100 | 1151 | 98 in | 1017 | 84 in |
| 6000 | 7300 | 1378 | 120 in | 1217 | 100 in |
The arithmetic is unforgiving at the long end. The Colosseum boardroom table is published at 2400, 3000 or 3600 mm long and 1500 mm deep. At 3600 mm it needs a 997 mm image height under the 5.3 rule, which is an 80 inch panel, and a 70 inch panel will not do it. Envy and Totem both run to 4200 mm, which asks for 1057 mm of image height, an 84 inch panel. EONA builds multi leg boardroom tables seating up to 24, a length well beyond anything in the table above, and at that point the answer stops being a panel: Flinders requires a dedicated projection screen for any image over 100 inches at clause 4.5.11.
Depth works the other way. A 1500 mm deep top puts nobody further from the screen, but it pushes the outer seats sideways, where the horizontal angle limit starts to bite. The published lengths, depths and seat counts are worth settling first, because a table that is the wrong length for the people is still wrong when the screen fits.

The seat nearest the screen is the one that fails
Most rooms fail the closest viewer rule, not the furthest, and boardrooms fail it worst. A table set 900 mm off the display wall with a chair at the head puts that eye somewhere near 1.1 m from the screen. The rule wants 2 times the image height: 1.99 m for an 80 inch panel, 2.43 m for a 98 inch, 3.23 m for a 130 inch. The bigger the screen, the further back the first seat has to be, which is the opposite of how screen size is usually decided.
Specifier's note. The closest viewer rule always governs over the vertical angle rule, so there is no point checking both. With the bottom of the image at the 1100 mm that Flinders and Curtin publish for a meeting room and the 1300 mm seated head height Melbourne publishes, the centre of the image sits half the image height plus 1100 mm above the floor. Satisfying the 15 degree limit to that centre needs roughly 1.87 times the image height less 746 mm, which is always a shorter distance than 2 times the image height. On an 80 inch panel the 15 degree rule is met at 1.11 m and the closest viewer rule is not met until 1.99 m. Check the horizontal distance, draw the seat out of the end position, and the vertical angle looks after itself.
There are two practical answers. Leave the head of the table empty and mark it on the furniture plan as a presenter position rather than a seat, which is what a horseshoe does by geometry. Or move the table back, which costs room length the base build usually will not give. Shrinking the screen is the third answer, and often the right one in a six person room.
How high the bottom of the image sits, and what gets in front of it
The published split is consistent: 1100 for a meeting room, 1200 for a teaching space. Curtin gives the same figures in metres and adds a preference for 1.35 m in a classroom where the screen is not interactive, because in a classroom the thing blocking the view is the head in front, and in a meeting room it is the table.
Furniture decides whether that 1100 mm survives. A 750 mm high table is not the problem. The problem is what sits on it. A monitor on a stand, a videoconference puck on a riser, a centre spine of planting, an upstand on a credenza below the screen: anything whose top lands above 1100 mm eats into the image from the bottom up for everyone on the far side. The meeting and boardroom tables that cause the least trouble here are the ones with their power and data integrated into the leg or recessed into the top rather than mounted on it.
Accessibility pulls the other way. An accessible position needs clear width between legs and a knee space, which a reading of AS 1428 against a furniture schedule sets out, and those positions tend to sit at the ends of a table, which is where the closest viewer rule is tightest. The two requirements have to be resolved on one drawing rather than in two packages.
How wide the table can be: the 45 and 60 degree arcs
Three of the four Australian documents give the same horizontal limit, 45 degrees, and describe it slightly differently. Melbourne puts the audience "within an arc of 45 degrees from either side of the centre line of projection/display". Curtin gives a maximum horizontal viewing angle of 45 degrees from the screen centre line. Flinders measures 45 degrees from straight ahead to the furthest vertical edge of the image, which is a different construction and a tighter one, because it is referenced to the edge rather than the centre.
AVIXA's standard uses a wider figure and a different geometry again. Its horizontal viewing area is "the area bounded by a line drawn 60 degrees from the perpendicular of each edge of the image", and that boundary is what determines the closest viewer rather than a stated multiple.
For a rectangular table on the centre line of a display the arc is rarely the binding constraint, because the people furthest off axis are also the people closest to the screen, and the closest viewer rule has already moved them. It becomes real in two cases: a table set off the room centre line, which happens whenever the display shares a wall with a door, and a horseshoe, which puts the inside faces of the two legs at an extreme angle to the end wall. A horseshoe photographs well, and the seats at the back of each leg are the ones to check.
What the AVIXA standard actually publishes, and why it has no multiple
ANSI/AVIXA V202.01:2026, Display Image Size for 2D Content in Audiovisual Systems, is the standard the university documents sit alongside and mostly do not cite. It is worth understanding because it answers a question the multiples cannot: how big does the smallest piece of content have to be.
Its unit is the element, defined by AVIXA as "a group of pixels conveying an item of information (e.g., a character at a given font size)". Percentage element height is "the ratio of element height to screen height expressed as a percentage". The viewing ratio is "calculated as the Farthest Viewer/Image Height", which is the same quantity the 5.3 and the 6 are values of. The difference is that AVIXA does not fix it. It publishes a minimum element height for each ratio band at an acuity factor of 200 for Basic Decision Making, and sets the acuity factor for Analytical Decision Making at 3438.
| Viewing ratio at least | And no more than | Minimum element height, per cent of image height |
|---|---|---|
| 0.80 | 1.00 | 0.50 |
| 1.00 | 1.50 | 0.75 |
| 1.50 | 2.00 | 1.00 |
| 2.00 | 3.00 | 1.50 |
| 3.00 | 4.00 | 2.00 |
| 4.00 | 5.00 | 2.50 |
| 5.00 | 6.00 | 3.00 |
| 6.00 | 7.00 | 3.50 |
| 7.00 | 8.00 | 4.00 |
| 8.00 | 9.00 | 4.50 |
| 9.00 | 10.00 | 5.00 |
Read that table against the 5.3 rule and it says something practical. At a viewing ratio between 5.00 and 6.00 the minimum element height is 3.00 per cent of the image height. On a 997 mm image that is a 30 mm character. Melbourne reaches the same place and states it plainly: the minimum element height "should be 3%". A room built to 5.3 or 6 times image height is a room in which content has to be set at roughly three per cent of image height, and a spreadsheet at nine point type will not read from the back whatever the furniture does. That is a template problem, better raised at design stage than discovered by a chief executive.

Training rooms, rows and flip top tables
In a training room the furthest viewer is the last row, and rows spend distance quickly. Allow 1500 mm of room depth per row for a 600 mm deep table, a chair and the circulation behind it, and three rows put the back row past 5 m from the front wall. The same arithmetic applies, with the last eye set by the back row rather than the end of a boardroom table.
This is where reconfigurable tables earn their place and also create a trap. Nexus Flip is published at 900 to 2100 mm wide with two connectors, and the U.R and I.AM tilt top tables from Thinking Works do the same job on lockable castors. A room set in rows for a presentation and in clusters for a workshop has two different furthest viewers, and the cluster layout usually puts somebody past 45 degrees off axis or facing away from the screen. Nominate the presentation layout as the one the sightlines are designed for, mark it on the room data sheet, and accept that the workshop layout is not a viewing layout. Universities publish their teaching table sizes and seat spacings for the same reason.
Where a pod is doing the work instead of a built room the geometry is fixed by the manufacturer, and the pod comparison covers the table size inside each model.
A short checklist for the furniture drawing
- Get the image height, not the diagonal. For 16:9, height is about 0.56 of the width. The Flinders table publishes it for nine sizes.
- Adopt one rule and write it on the drawing. 5.3 times or 6 times. Mixing them between the furniture package and the audiovisual package is how a room ends up 700 mm too long.
- Measure the last eye, not the last chair. Set back plus table length plus about 400 mm for a head seat.
- Check the end seats against 2 times the image height and delete the ones that fail rather than arguing about them later.
- Keep everything on the table below 1100 mm where the bottom of the image is at 1100 mm, which rules out most monitors and some planting.
- Nominate the layout the sightlines belong to in any room with mobile tables.
Geneva specifies and delivers the meeting and boardroom tables these rooms are built around, and the sightline arithmetic is quicker to run before a table length is locked than after. If you are sizing a boardroom table against a display that is already chosen, or a display against a table that is, send us the room dimensions and the screen size and we will tell you which seats the published rules put outside the viewing area.
Sources
- AVIXA, Analytical and Basic Decision Making Calculations and Learn more about display size, for ANSI/AVIXA V202.01:2026, the viewing ratio definition, the acuity factors of 200 and 3438, the Basic Decision Making element height table and the 60 degree horizontal viewing area.
- The University of Melbourne Audio Visual Endpoints Design Standards, Section 18: AV, July 2026, sections 18.5.2 and 18.5.4.
- Flinders University Audio Visual Technology Standards, Version 1.2, 5 September 2025, clauses 4.5.1, 4.5.2, 4.5.11 and 4.5.12.
- Curtin University Project Delivery Guidelines, Audiovisual Guidelines Part 6, Room Design and Construction, Rev. No. 2, December 2019, sections 4.1, 5.1, 5.2 and 5.3.
- University of South Australia Audio-Visual Standards and Specifications, Revision 2.0.
- Microsoft, Meeting room guidance for Teams and Plan Microsoft Teams Rooms.
- Published product dimensions from the Geneva by Design and Thinking Works product pages linked above.
Frequently asked
How far can the last seat be from a screen in a meeting room?
Between 5.3 and 6 times the image height, depending on which published rule the project adopts. Curtin University and Flinders University both publish a maximum viewing distance of 5.3 times the image height, and Flinders allows 6 times with prior approval. The University of Melbourne publishes 6 times as the furthest viewer and treats that rule as essential. On an 80 inch 16:9 panel with a viewable image height of 997 mm, that is 5.3 m under the first rule and 6.0 m under the second.
What is the minimum distance from a screen to the nearest seat?
Curtin and Flinders both publish a closest viewing distance of 2 times the image height. The University of Melbourne publishes 1.732 times. On a 997 mm image height that is 1.99 m or 1.73 m. This is the figure a boardroom usually breaches, because a seat at the head of the table nearest the display sits far closer than 2 m from the screen.
How high should the bottom of a meeting room screen be?
Flinders publishes 1100 in a meeting room and 1200 in a teaching space, written as AFFL with no unit printed beside the figure. Curtin publishes the same split in metres, a minimum of 1.1 m for a meeting space and 1.2 m for a classroom, and states a preference for 1.35 m in a classroom where the screen is not interactive. Curtin also caps the top edge of an interactive whiteboard at 2.1 m.
Does the AVIXA standard give a viewing distance multiple?
No. ANSI/AVIXA V202.01:2026 works from the size of the smallest element of content rather than from a fixed multiple. Its viewing ratio is the farthest viewer distance divided by the image height, and for Basic Decision Making at an acuity factor of 200 the published table sets a minimum element height for each ratio band, from 0.50 per cent of image height at a ratio under 1.00 to 5.00 per cent at a ratio of 10.00. The Analytical Decision Making acuity factor is 3438.
What screen size does a 3600 mm boardroom table need?
An image height of at least 925 mm under the 5.3 times rule, which is an 80 inch 16:9 panel, or at least 817 mm under the 6 times rule, which is a 70 inch panel. That is taking 900 mm from the display wall to the near edge of the top and 400 mm from the far edge to the eye of a person seated at the head, which puts the last eye 4900 mm from the screen. Lengthen the table or add a head seat and the panel grows with it.